Electrical Safety Guidelines - Cisco IPS-4255-K9 - Intrusion Protection Sys 4255 Installation Manual

Intrusion prevention system appliance and module installation guide for ips 7.0
Table of Contents

Advertisement

Chapter 1
Introducing the Sensor

Electrical Safety Guidelines

Before working on a chassis or working near power supplies, unplug the power cord on AC units;
Warning
disconnect the power at the circuit breaker on DC units.
Follow these guidelines when working on equipment powered by electricity:
OL-18504-01
Before beginning procedures that require access to the interior of the chassis, locate the emergency
power-off switch for the room in which you are working. Then, if an electrical accident occurs, you
can act quickly to turn off the power.
Do not work alone if potentially hazardous conditions exist anywhere in your work space.
Never assume that power is disconnected from a circuit; always check the circuit.
Look carefully for possible hazards in your work area, such as moist floors, ungrounded power
extension cables, frayed power cords, and missing safety grounds.
If an electrical accident occurs, proceed as follows:
Use caution; do not become a victim yourself.
Disconnect power from the system.
If possible, send another person to get medical aid. Otherwise, assess the condition of the victim
and then call for help.
Determine if the person needs rescue breathing or external cardiac compressions; then take
appropriate action.
Use the chassis within its marked electrical ratings and product usage instructions.
Install the sensor in compliance with local and national electrical codes as listed in
Compliance and Safety Information for the Cisco Intrusion Prevention System 4200 Series
Appliance
Sensor.
The sensor models equipped with AC-input power supplies are shipped with a 3-wire electrical cord
with a grounding-type plug that fits only a grounding-type power outlet. This is a safety feature that
you should not circumvent. Equipment grounding should comply with local and national electrical
codes.
The sensor models equipped with DC-input power supplies must be terminated with the DC input
wiring on a DC source capable of supplying at least 15 amps. A 15-amp circuit breaker is required
at the 48 VDC facility power source. An easily accessible disconnect device should be incorporated
into the facility wiring. Be sure to connect the grounding wire conduit to a solid earth ground. We
recommend that you use a Listed closed-loop ring to terminate the ground conductor at the ground
stud. The DC return connection to this system is to remain isolated from the system frame and
chassis.
Other DC power guidelines are listed in
Cisco Intrusion Prevention System 4200 Series Appliance
Cisco Intrusion Prevention System Appliance and Module Installation Guide for IPS 7.0
Regulatory Compliance and Safety Information for the
Sensor.
Site and Safety Guidelines
Regulatory
1-31