Section Seven: BEFORE CALLING FOR SERVICE
Do-It-Yourself
Maintenance
OVEN LIGHT BULB REPLACEMENT
Replace onlywith
a 10-watt, halogen appliance
light bulb. DO NOT USE
a standard
household
light bulb in any oven or any bulb over 10 watts.
To Replace
the Light Bulb:
1.
Turn oven light switch to the off position.
Let bulb and cover cool
completely.
2.
Remove
the light cover.
3.
Remove
the burned-out
bulb.
Replace
it with a 10-watt
halogen
appliance
light bulb only.
Don't touch
bulb with fingers.
Follow
bulb
manufacturer's
instructions.
4.
Replace
cover.
Turn circuit back on, if need be.
(See Caution.)
CAUTION:
Before
replacing
the
light
bulb,
be certain
the
Oven
Light Switch is in the off posi-
tion. Let bulb and covercool
completely
before
touching.
If the light bulb glass comes
loose from the base, turn the
power tothe oven OFF atthe
circuit breaker
panel, before
attempting
to remove
the
bulb base from the socket.
POWER
FAILURE
In the event
of a power
failure,
only the standard
burners
can be lighted
manually.
It is necessary
to
light each standard
burner individually.
If the range's cooktop
is being used when the power
failure
occurs, turn all of the burner control
knobs to
the OFF position.
Then, the standard
burners can be
lighted
by holding
a match at the ports and turning
the control
knob to the HI position.
Wait
until the
flame
is burning
all the way around the burner cap
before
adjusting
the flame to the desired
height.
The two ExtraLow _ burners
on the far left side cannot
be used during a power failure.
Be sure toturn
them
OFF if a power failure
occurs
because
they will not
turn back on until both control knobs are turned OFF
and then turned
back on again.
See "What to do if
you Smell Gas," inside front cover.
If you
have
low
gas pressure,
contact
your
gas
company.
INTERMITTENT
OR CONSTANT
IGNITER
SPARKING
Intermittent
or constant
sparking
of the sealed
gas surface
burners
can result from a number
of prevent-
able conditions.
Eliminate
these conditions
as indicated
in the chart.
SYMPTOM
CAUSE
REMEDY
Intermittent
sparking
Ceramic
igniter is wet or dirty.
Carefully
dry or clean igniter.
More than four clicks of
igniter
before
lighting
Burner ports are clogged.
Improper
fit of burner cap onto
burner
base.
Clean ports on burner cap
with a wire, a needle or
straightened
paper clip.
Align burner cap properly
on burner
base.
Constant
Sparking
Range
is not properly
grounded.
Refer to Installation
Instructions.
Have a qualified
electrician
ground the range properly.
Electrical
power supply
is
incorrectly
polarized.
Refer to Installation
Instructions.
Have a qualified
electrician
ground the range properly.