Output Signal - Omron ZFX-C10 User Manual

Vision sensor with built-in lcd monitor
Hide thumbs Also See for ZFX-C10:
Table of Contents

Advertisement

Example
Command
Bank switching
Bank group switching
Model re-registration

Output Signal

Measurement results are output each time a measurement is made. Measurement values and judgment
results can be output as the measurement results.
Up to 32 data are output respectively (except for overall judgment result outputs.) They are output for the
number of times in the expression set at "Calculation".
Expression
Data is output only when the ZFX-C is in the RUN mode; data is not output when the ZFX-C is in ADJ mode.
p.96
Note
After measurements have been made in the RUN mode, the data that is output to the OR and DO signals is retained
until new measurements are made in the RUN mode. The status of these output is retained even if the ZFX-C is
switched from the RUN mode to another Mode.
ZFX-C User's Manual
Example
Switching to bank 2.
Switching to bank group 2.
Re-registering the model of item 6
000
000
Data output
001
001
002
002
Data 31
127
Judgment
000
000
001
001
002
002
output
Judgment 31
127
000
000
001
001
002
002
Variable 31
127
DI7
DI6
DI5
DI4
DI3
0
1
0
0
0
1
1
0
0
0
1
0
0
0
0
Only the preset data is output.
For example, only data 0 and data 7 are
output when data 0 and data 7 is set.
Only the preset judgment is output.
For example, only judgments 0 to 15 are
output when judgment 0 is set, and the
remaining judgment results are not output.
DI2
DI1
DI0
0
1
0
0
1
0
1
1
0
137
Signal I/O

Advertisement

Table of Contents
loading

Table of Contents