  • Page 1 Cat. No. Q28E-EN-01 Smart Sensor ZFX-C Appendix for ZFX-C_-CD Code reading functionality USERS MANUAL...
  • Page 3 Measurement region Important Reading will end in error if the barcode type is incorrectly set. Set the barcode type before starting reading. When AUTO setting is executed, the captured barcode is read, and the following items can be set: •Code type p.6 •Direction (for Pharma only) p.6...
  • Page 4 Registering the master data for verification Master data are used for verification. After reading process, the read text string can be verified against the pre- registered master data. 32 sets of master data can be registered as text string. Also, processing to be executed from this measurement item onwards can also be branched according to the verification results when measurement control function is ON.
  • Page 5 Note ASCII code table The following table shows the ASCII codes that can be used for manual registration of master data and also for registering characters of Limits. Upper 4 bits Lower 4 bits Threshold This function sets the judgment conditions.
  • Page 6 Image adjustment (if necessary) The following items can be changed and set to the image of the measurement target. MENU mode - [Setup] - [Item] - [Img Adj] Item Description Select Camera For details, refer to Chapter 3 "Image Adjustment" of the ZFX User's Manual.
  • Page 7 Output function of the read results •The output order The read results can be output on the serial interface. When the calculation results are output at the same time, the calculation results are output first, followed by the read results (text string).
  • Page 8 Only codes that can be registered manually and 2-byte characters can be displayed as text string in the result display screen. Other character codes (including control codes) that are read are displayed as spaces. The read string is displayed up to 32 characters. ···...
  • Page 9 Measurement region Important Reading will end in error if the 2D Code type is incorrectly set. Set the code type before starting reading. When AUTO setting is executed, the captured 2D barcode is read, and the following items can be set: •Code type p.11...
  • Page 10 Registering the master data for verification Master data are used for verification. After reading process, the read text string can be verified against the pre- registered master data. 32 sets of master data can be registered as text string. Also, processing to be executed from this measurement item onwards can also be branched according to the verification results when measurement control function is ON.
  • Page 11 Range: 0 to 1024 Characters The read text string is judged as OK when it is the same as the characters in this menu. Up to 32 characters can be set. Check available characters in the ASCII table. 2-byte characters, 1-byte kana characters and control codes cannot be entered.
  • Page 12 NG) ASCII code table p.3 Partial output OFF (default value) Sets whether or not to specify a range in the read data to output from when [Output characters] is set to ON. Output digit 1 to 1024 (default value Sets the first and last digit positions to output.
  • Page 13 Decode condition detailed settings Be Sure to set the detailed conditions for the code type. Set other items as required. By AUTO setting, Code type, Mirror, Code color, Shape (Data Matrix) are set automatically. MENU mode - [Setup] - [Item] - [Detail]- [Decode condition]...
  • Page 14 Size Inspection Multi Colors This function measures the areas of up to four colors simultaneously, which enables to measure the difference of color pattern. Each of the area values and differences with reference values can be output. Important This function cannot be used when a monochrome camera is connected.
  • Page 15 Description Area 1 to 4 Sets the range of the area to be judged as OK. Range: 0 to 9999999.999 (When calibration is OFF, the range becomes 0 to 307200.) Detailed settings (if necessary) Adjust the detailed conditions, if necessary.
  • Page 16 AUTO button (RUN mode) In the RUN mode, all measurement items can be batch-set automatically by pressing the [AUTO] button. AUTO setting content differs with each measurement item. For details, see "AUTO Setting" in Chapter 7 of the ZFX User's Manual.
  • Page 17 Character codes that cannot be displayed (e.g. control codes) are displayed as spaces. When text strings are output, the following control codes are converted before they are output. When setting text strings, use the codes in the "After conversion" column. Text code...
  • Page 18 Multi Color Data No. Parameter Output Range Judgment result 0 : OK -1 : NG -2 : not measured Individual area1 0 to 9999999.999 Individual area2 0 to 9999999.999 Individual area3 0 to 9999999.999 Individual area4 0 to 9999999.999 Individual reference area1 0 to 9999999.999...
  • Page 19 Data No. Parameter Range Verification func. 0: OFF, 1: ON Verified master data 0: All master data, 1: Master0, 2: Master1, 3: Master2, ... 32: Master31 Partial verification 0: OFF, 1: ON Last compared digit 1 to 1024 First compared digit...
  • Page 20 Data No. Parameter Range Verification func. 0: OFF, 1: ON Verified master data 0: All master data, 1: Master0, 2: Master1, 3: Master2, ... 32: Master31 Partial verification 0: OFF, 1: ON Last compared digit 1 to 1024 First compared digit...
  • Page 21 Parameter Range Fill profile 0: OFF, 1: ON Calibration 0: OFF, 1: ON Coordinates mode 0: Normal, 1: Pos. correction Auto THset +/- 0.000 to 9999999.999 Area judgment (upper limit) 0.000 to 9999999.999 Area judgment (lower limit) 0.000 to 9999999.999 Individual area1 upper limit value 0.000 to 9999999.999...
  • Page 22 MEMO ZFX-C1_/C2_-CD Additional Functions Instructions...