Possible output results
The following values can be output when expressions are set.
Item
Description
Judgment result
The judgment result is output. (0:OK, -1:NG, -2: not measured)
Hue
The hue average is output. (0 to 360.0)
Saturation
The saturation average is output. (0 to 100.0)
Value
The value average is output. (0 to 100.0)
Hue deviation
The hue fluctuation is output. (0 to 180.0)
Saturation deviation
The saturation fluctuation is output. (0 to 50.0)
Value deviation
The value fluctuation is output. (0 to 50.0)
Reference hue
The hue when the measurement region is set is output.
(0 to 360.0)
Reference saturation
The saturation when the measurement region is set is output.
(0 to 100.0)
Reference value
The value when the measurement region is set is output.
(0 to 100.0)
Hue difference
The hue difference obtained by "measurement value - reference
value" is output. (-360.0 to 360.0)
Saturation difference
The saturation difference obtained by "measurement value -
reference value" is output. (-100.0 to 100.0)
Value difference
The value difference obtained by "measurement value - reference
value" is output. (-100.0 to 100.0)
Reference hue deviation The hue fluctuation when the measurement region is set is
output. (0 to 180.0)
Reference saturation
The saturation fluctuation when the measurement region is set is
deviation
output. (0 to 50.0)
Reference value
The value fluctuation when the measurement region is set is
deviation
output. (0 to 50.0)
Hue deviation difference The hue deviation difference obtained by "measurement value -
reference value" is output. (-180.0 to 180.0)
Saturation deviation
The saturation deviation difference obtained by "measurement
difference
value - reference value" is output. (-50.0 to 50.0)
Value deviation
The value deviation difference obtained by "measurement value -
difference
reference value" is output. (-50.0 to 50.0)
Hue maximum/minimum The hue maximum/minimum values are output. (0 to 360.0)
Saturation maximum/
The saturation maximum/minimum values are output. (0 to 100.0) Max. S/Min. S
minimum
Value maximum/mini-
The value maximum/minimum values are output. (0 to 100.0)
mum
Nos. indicating hue, saturation and value p.190
ZFX-C User's Manual
Message
Judge (JG)
H average (H)
S average (S)
V average (V)
H deviation (HD)
S deviation (SD)
V deviation (VD)
Ref. H average (SH)
Ref. S average (SS)
Ref. V average (SV)
H average dif. (DH)
S average dif. (DS)
V average dif. (DV)
Ref. H deviation (SHD)
Ref. S deviation (SSD)
Ref. V deviation (SVD)
H deviation dif. (DH)
S deviation dif. (DSD)
V deviation dif. (DVD)
Max. H/Min. H
(HH, LH)
(HS, LS)
Max. V/Min. V
(HV, LV)
Setting Measurement Items
75