Switching The Image Display Method; Using A Saved Image To Perform Re-Measurement - Omron ZFX-C10 User Manual

Vision sensor with built-in lcd monitor
Hide thumbs Also See for ZFX-C10:
Table of Contents

Advertisement

Switching the Image Display Method

In the Individual results display or Position correction display, you can hide or reduce the size of images that
are displayed simultaneously with measurement information. Each press of the ↑ UP key/↓ DOWN key
switches the image display as follows:
In the Stored image display, the image display is switched between 1/4 display and full display.
Full display
Individual result
OK
353ms
0.Bank00
0.Pattern Search
Judge
OK
Correlation 92
Position X 462
Position Y 352
Angle
15
Previous
Next
Adjust
Display sw
In the "Variables list," "Data list" or "Judgments list" display, each press of the ↑ UP key/↓ DOWN key toggles
display/hide of the camera image.
No image
OK
353ms
Variables list( 0-15)
Var.0 *******.***
Var.8
*******.***
Var.1 *******.***
Var.9
*******.***
Var.2 *******.***
Var.10 *******.***
Var.3 *******.***
Var.11 *******.***
Var.4 *******.***
Var.12 *******.***
Var.5 *******.***
Var.13 *******.***
Var.6 *******.***
Var.14 *******.***
Var.7 *******.***
Var.15 *******.***
Previous
Next
Adjust
Dsplay SW

Using a Saved Image to Perform Re-measurement

Re-measurement can be performed using a measurement image saved in the RUN mode. If the ← L key/→ R
key is pressed in the Individual results display or All results/Region display, the screen switches to the saved
image and re-measurement is executed.
Note
Up to 100 images can be saved. Images that were judged as NG also can be saved.
Measurement Image Save Conditions, p.121
ZFX-C User's Manual
1/4 display
Individual result
OK
353ms
0.Bank00
0.Pattern Search
Judge
OK
Correlation 92
Position X 462
Position Y 352
Angle
15
Previous
Next
Adjust
Display sw
The 1/4 display is available only
for the individual results display
and position correction display.
Image display
OK
353ms
Variables list( 0-15)
Var.0 *******.***
Var.8
*******.***
Var.1 *******.***
Var.9
*******.***
Var.2 *******.***
Var.10 *******.***
Var.3 *******.***
Var.11 *******.***
Var.4 *******.***
Var.12 *******.***
Var.5 *******.***
Var.13 *******.***
Var.6 *******.***
Var.14 *******.***
Var.7 *******.***
Var.15 *******.***
Previous
Next
Adjust
Dsplay SW
Checking/Adjusting the Measurement - ADJ Mode
No image
Individual result
OK
353ms
0.Bank00
0.Pattern Search
Judge
OK
Correlation 92
Position X 462
Position Y 352
Angle
15
Prev.
Next
Adjust
Display sw
The image is not displayed
while a saved image is dis-
played.
107

Advertisement

Table of Contents
loading

Table of Contents