Bright/Color Inspection

Bright

Use this item to measure the brightness of measurement targets. The density average and density deviation
(brightness fluctuations) are output. Change in brightness can be used to inspect whether or not parts are
present.
Setup
Region settings
This function sets the measurement region.
MENU mode - [Setup] - [Item] - [Region]
Setup Item
Description
Measurement region
This function sets the region to be measured.
Reference registration
When the measurement region is set, measurement is executed on the display image,
and the result of execution is registered as the reference value. To re-register only refer-
ence values, you can use this function to re-register only reference values based on the
image currently on screen.
Threshold
This function sets the judgment conditions.
MENU mode - [Setup] - [Item] - [Limits]
Setup Item
Description
Density average
Sets the range of the density average to be judged as OK.
Range: 0 to 255.0
Density deviation
Sets the range of the density deviation to be judged as OK.
Range: 0 to 127.0
ZFX-C User's Manual
Measurement
Measurement region
Setting the Region p.178
Density average,
density deviation
Setting Measurement Items
71