Normal
Set the conditions required for performing serial communications in the normal mode.
MENU mode - [System] - [Comm] - [Normal]
Setup Item
Setting value
Delimiter
CR (default value), LF, CR+LF
Parallel Communication
Parallel communication
Set the conditions required for performing parallel communications.
MENU mode - [System] - [Comm] - [Parallel]
Setup Item
Description
Polarity
Sets the ON condition when the judgment result is output to the DO0 to DO15 and OR sig-
nals.
Output cycle
Sets the output cycle for the measurement results. Set a time that is "Gate ON delay +
Gate ON time" or more and that is shorter than the measurement cycle.
Gate ON delay
Sets the time from output of the measurement result to the DO0 to 15 signals until the
GATE signal turns ON. This is the time to wait until stable output data can be obtained. Set
a value longer than the ON delay/OFF delay time of the external device.
Gate ON time
Sets the time that the GATE signal is ON. Set a value that allows the external device to
capture the measurement result.
Handshaking
Sets the output method for the measurement results.
Timeout
Sets the time until the timeout error is output. A timeout error occurs when there is no
response from the external device within the preset time.
ZFX-C User's Manual
NG: ON: Signals turn ON when the judgment is NG. (default value)
OK: ON: Signals turn ON when the judgment is OK.
Range: 2.0 to 10000.0 ms (default value: 10.0 ms)
Range: 1.0 to 1000.0 ms (default value: 0.0 ms)
Range: 1.0 to 1000.0 ms (default value: 5.0 ms)
OFF: Measurement results are output asynchronously with external devices.
(default value)
ON: Measurement results are output synchronously with external devices.
Range: 1.0 to 60.0 s (default value: 10.0 s)
113