Omron ZFX-C10 User Manual page 119

Vision sensor with built-in lcd monitor
Hide thumbs Also See for ZFX-C10:
Table of Contents

Advertisement

Output Conditions
When "Serial output" or "SD card" is output as the data output destination, set the output form and output
format.
ASCII format
When outputting measurement values in ASCII format, set the following items.
MENU mode - [System] - [Output] - [Date format (Serial)/(SD Card)]
Setup Item
Description
Output form
Selects ASCII.
Digits of integer
Sets the number of output digits of the integer section. When "0" is selected, all of the dig-
its of the data are output shifted to the left.
When there are fewer data digits than the preset number of digits, "0" is inserted in free
digits.
When there are more data digits than the preset number of digits, "9" is output for the pre-
set number of digits.
Digits of decimal
Sets the number of output digits past the decimal point. When "0" is selected, digits past
the decimal point are rounded up to the nearest integer.
Field separator
Sets the separator between individual output data items.
Decimal separator
Sets the number of digits past the decimal point.
Record separator
Sets the separator between individual output data records.
Display at time
Prefixes the output data with time information.
File name
Sets the name of the output file. (only when SD card is selected) The directory "OUTFILE"
is automatically created in the root directory of the SD card. Output files are stored in this
directory.
Note
Output format
< Measurement value of data 0 >,
When Display at time is set to "ON", the data is prefixed with the time information.
<Year/month/day>, <Hours/minutes/seconds>, <Measurement value of data 0>, <Measurement value of data 1> ... <Measurement value of data 31> Delimiter
Example:
Example:
On August 1st, 2007
At 1 minute, 20 seconds past 12 am
→2007/8/1
→12:01:20
ZFX-C User's Manual
Range: 0 to 8 (default value: 8)
Range: 0 to 3 (default value: 3)
Range: None, Comma (default value), Tab, Space, Semicolon
Range: None, Period (default value), Comma
Range: None, Comma, Tab, Space, Delimiter (default value)
Range: OFF (default value), ON
< Measurement value of data 1>... < Measurement value of data 31 > Delimiter
Field separator
Record separator
117
System Settings

Advertisement

Table of Contents
loading

Table of Contents