Signal I/O

S
Input
ignal
The following signals can be input when the ZFX-C is in the RUN mode.
Measurement Timing Input
A one-time measurement is performed if the TRIG signal is turned ON.
Command Input
Input format
DI8
DI7
Commands
Parallel command confirmation signal
Commands
Signals DI0 to DI7 can input the following commands. Allow at least 5 ms after DI0 to DI7 are determined to be
ON before turning DI8 ON.
Command
Continuous measurement
Bank switching
Bank group switching
Model re-registration
In the above table, a "0" indicates the signal is OFF, a "1" indicates the signal is ON. A "*" indicates that the
ZFX-C does not read the bit status, so the bit status can be either 0 or 1.
136

Signal I/O

DI6
DI5
DI4
DI3
Description
Measurements continue while the
command is being input.
Switches the bank to measure.
Switches the bank group data.
Registers the model again based
on the last measurement image
that was read.
DI2
DI1
DI0
Parameters
DI7
DI6
0
0
0
1
1
1
1
0
DI5
DI4
DI3
DI2
DI1
0
*
*
*
*
0
Bank number
0
Bank group number
0
Item number
ZFX-C User's Manual
DI0
*