HUE

Use this item to measure the color of measurement targets. This item can be used to measure whether or not
different-colored products are mixed in, for example. Average hue, saturation and brightness value, and
respective deviations (fluctuations) can be output.
Important
This function cannot be used when a monochrome camera is connected.
Setup
Region settings
This function sets the measurement region.
MENU mode - [Setup] - [Item] - [Region]
Setup Item
Description
Measurement region
This function sets the region to be measured.
Reference registration
When the measurement region is set, measurement is executed on the display image,
and the result of execution is registered as the reference value. To re-register only refer-
ence values, you can use this function to re-register only reference values based on the
image currently on screen.
ZFX-C User's Manual
Measurement
Measurement region
Setting the Region p.178
Hue, saturation,
brightness
value
Setting Measurement Items