Omron ZFX-C10 User Manual page 49

Vision sensor with built-in lcd monitor
Hide thumbs Also See for ZFX-C10:
Table of Contents

Advertisement

Threshold
This function sets the judgment conditions.
MENU mode - [Setup] - [Item] - [Limits]
Setup Item
Description
Correlation
Sets the range of the correlation to be judged as OK.
Range: 0 to 100
Position XY
Sets the range of movement in the X- and Y- axes of the measurement target to be judged
as OK.
Range: -9999.999 to 9999.999
(When calibration is OFF, the range of movement for positions X and Y are 0 to 640 and 0
to 480, respectively.)
Angle
Sets the range of rotation angle to be judged as OK.
Range: -180 to 180
Search point
Sets the number of search candidates to be judged as OK.
(enabled only when Veri-
Range: 0 to 99
fication is set to [ON])
Image adjustment (if necessary)
The following items can be changed and set to the image of the measurement target.
MENU mode - [Setup] - [Item] - [Img Adj]
Item
Description
Color filter
Filtering
BGS* level
*BGS: Background Suppression
ZFX-C User's Manual
-
+
For details, see "Image Adjustment". p.80
Setting Measurement Items
47