Explanation of operation
(1) When the measurement trigger (TRIG signal) is input from the external device, measurement is executed
once synchronized with the rising edge of the TRIG signal (OFF -> ON).
(2) The GATE signal is used to control the timing at which the external device captures measurement results.
Set the Gate ON delay (T3) and Gate ON time (T4) so that T3+T4<T5.
(3) When parallel output is set to "ON" as the data output destination, data is output for the number of times in
the expression set at "Calculation (data)" (maximum 32 times). When parallel output is OFF, data is not
output.
(4) When parallel output is set to "ON" as the judgment output destination, judgment is output for the number
of times in the expression set at "Calculation (judgment)" (maximum twice). When parallel output is OFF,
judgment is not output.
(5) The overall judgment is output. Overall judgment is NG if there is even one NG for the preset measurement
items and judgment results in the expression. In the case of level output, the ON/OFF status of the OR
signal does not change until the next output as shown in this example.
(6) When the timing for turning the ENABLE signal ON is set to "end of image input", a delay occurs until
output is started after the ENABLE signal turns ON as measurement is also executed after the ENABLE
signal turns ON. Do not input the next trigger until measurement is completed.
Continuous Measurement
OFF
DI0
to DI7
ON
DI8
OFF
ON
OFF
ENABLE
ON
OFF
OR
ON
OFF
DO
ON
OFF
GATE
ON
142
Timing Charts
(4)
Overall judgment
Judgment
Data 0
(6)
0 to 15
Judgment
Data 1
16 to 31
T4
T5
T6
T7
(7)
Overall judgment
Judgment
Data 0
0 to 15
Data 1
ZFX-C User's Manual
Judgment
16 to 31