Relation Between Screens And Function Blocks - Omron CX-PROCESS MONITOR PLUS V2 - 01-2007 Operation Manual

Table of Contents

Advertisement

CX-Process Monitor Plus
1-1-5

Relation between Screens and Function Blocks

Screen
Loop Control Boards: Make HMI settings
User-
Overview
---
defined
Screen
screens
Control
Basic PID, Advanced PID, Blended PID
Screens
(Block Model 013), Batch Flowrate Capture
(Block Model 014), Indication and Setting,
Indication and Operation, Ratio Setting,
Indicator, 2-Position ON/OFF, 3-Position
ON/OFF, High/Low Alarm, Segment Pro-
gram 2, ON/OFF Valve Manipulator, Motor
Manipulator, Reversible Motor Manipulator,
Motor Opening Manipulator, Timer, Counter
Tuning
Segment Program 2
Screens
Trend
Basic PID, Advanced PID, Blended PID
Screens
(Block Model 013), Batch Flowrate Capture
(Block Model 014), Indication and Setting,
Batch Trend
Indication and Operation, Ratio Setting,
Screen
Indicator, 2-Position ON/OFF, 3-Position
ON/OFF (PV, SP, MV only), Segment Pro-
gram 2, ON/OFF Valve Manipulator, Motor
Manipulator, Reversible Motor Manipulator,
Motor Opening Manipulator
Segment
Segment Program 2
Program 2
Screen
Graphic
Same tag ITEMs as for Control screens.
Screens
Annunciator
Same tag ITEMs as for Control screens.
Screens
Operation
---
Guide
Screens
System
---
Monitor
Screens
System
Alarm Log
Contacts for which alarms were automati-
screens
Screens
cally allocated when registering tags
Operation
---
History
Screens
System
---
Monitor Log
Screens
The relation between screens and function blocks is shown below.
Loop Control Unit: Register Send All
Blocks and Receive All Blocks blocks
in the System Common block
Input Selector
Internal Switch
block (Block
block (Block
Model 162)
Model 209)
---
---
Analog signal
Contact signal
or analog value
or contact
parameters
parameters
---
---
Analog signal
Contact signal
or analog value
or contact
parameters
parameters
Can be desig-
Can be desig-
nated as
nated as
expansion mea-
expansion mea-
surement tags
surement tags
Analog signal
Contact signal
or analog value
or contact
parameters
parameters
---
Contact signal
or contact
parameters
---
Contact signal
or contact
parameters
---
---
---
Contacts for
which alarms
were automati-
cally allocated
when register-
ing tags
---
---
---
---
Section 1-1
Constant
Generator
block (Block
Model 166)
---
Analog output
---
Analog output
Can be desig-
nated as
expansion mea-
surement tags
Analog output
---
---
---
---
---
---
15

Advertisement

Table of Contents
loading