7 PLC Setup
Origin Return Settings
Name
1
Speed
2
Acceleration Ratio (rate)
3
Deceleration rate
7-2-9

Built-in AD/DA: Built-in Analog I/O Settings

AD 0CH/AD 1CH: Analog Input Settings
Name
1
Analog Input 0: Use
1-1
Range
1-2
Use averaging
2
Analog Input 1: Use
2-1
Range
2-2
Use averaging
DA 0CH: Analog Output Settings
Name
1
Analog Output 0: Use
1-1
Range
7-16
Default
0 pps (disabled)
1 pps
:
100,000 pps
0 (disabled)
1 (pulse/4 ms)
:
65,535 (pulse/4 ms)
0 (disabled)
1 (pulse/4 ms)
:
65,535 (pulse/4 ms)
Default
Do not use.
Do not use.
Use.
-10 to 10 V
-10 to 10 V
0 to 10 V
1 to 5 V
0 to 5 V
0 to 20 mA
4 to 20 mA
Do not use.
Do not use.
Use.
Do not use.
Do not use.
Use.
-10 to 10 V
-10 to 10 V
0 to 10 V
1 to 5 V
0 to 5 V
0 to 20 mA
4 to 20 mA
Do not use
Do not use.
Use.
Default
Do not use.
Do not use.
Use.
-10 to 10 V
-10 to 10 V
0 to 10 V
1 to 5 V
0 to 5 V
0 to 20 mA
4 to 20 mA
When setting is read by
Possible settings
At start of operation
At start of operation
At start of operation
When setting is read by
Possible settings
When power is turned ON
When power is turned ON
When power is turned ON
When power is turned ON
When power is turned ON
When power is turned ON
When setting is read by
Possible settings
When power is turned ON
When power is turned ON