Omron CP1E CPU UNIT SOFTWARE User Manual page 418

Cp1e cpu unit software
Table of Contents

Advertisement

Appendices
Address
Name
Words
Bits
A327
10
High-speed Counter 5
Count Direction
A339 to
Maximum Differentia-
A340
tion Flag Number
A351 to
Calendar/Clock Area
A354
(N/NA-t
ype
CPU
Unit
only)
A360 to
01 to
Executed FAL Number
A391
15
Flags
A-64
Function
This flag indicates whether the
high-speed counter is currently being
incremented or decremented. The
counter PV for the current cycle is com-
pared with the PV in last cycle to deter-
mine the direction.
OFF: Decrementing
ON: Incrementing
These words contain the maximum
value of the differentiation flag num-
bers being used by differentiation
instructions.
These words contain the CPU Unit's
internal clock data in BCD. The clock
can be set from the CX-Programmer,
with the DATE instruction, or with a
FINS command (CLOCK WRITE,
0702).
A351.00 to A351.07:
Seconds (00 to 59)(BCD)
A351.08 to A351.15:
Minutes (00 to 59)(BCD)
A352.00 to A352.07:
Hours (00 to 23)(BCD)
A352.08 to A352.15:
Day of the month (01 to 31)(BCD)
A353.00 to A353.07:
Month (01 to 12)(BCD)
A353.08 to A353.15:
Year (00 to 99)(BCD)
A354.00 to A354.07:
Day of the week (00 to 06)(BCD)
00: Sunday
01: Monday
02: Tuesday
03: Wednesday
04: Thursday
05: Friday
06: Saturday
Note 1 The data will be unstable if the
capacitor becomes dis-
charged. Write the ladder pro-
gram and design the overall
system to handle any prob-
lems that might occur if this
data becomes unstable.
2 In an E-type CPU Uint, or if the
clock data is not set for an
N/NA-type CPU Unit, the data
will be for 1:01.01 on Sunday
January 1, 2001.
The flag corresponding to the specified
FAL number will be turned ON when
FAL is executed. Bits A360.01 to
A391.15 correspond to FAL numbers
001 to 511.
Note The flag will be turned OFF when
the error is cleared.
Status
after
Settings
mode
change
Cleared
See Func-
Cleared
tion col-
umn.
Retained
Retained
ON: That FAL was
Retained
Cleared
executed
OFF: That FAL wasn't
executed
CP1E CPU Unit Software User's Manual(W480)
Related
Status at
Write
flags,
startup
timing
settings
Setting used
for high-speed
counter, valid
during counter
operation.
Written at the
A295.13
start of opera-
tion
Written every
cycle
Refreshed
A402.15
when error
occurs.

Advertisement

Table of Contents
loading