Omron CP1E CPU UNIT SOFTWARE User Manual page 420

Cp1e cpu unit software
Table of Contents

Advertisement

Appendices
Address
Name
Words
Bits
A393
00 to
Built-in RS-232C Port
07
Polled Unit Communi-
cations Flags (CP1E
N/NA-type CPU Unit
only)
00 to
Built-in RS-232C Port
15
Reception Counter
(No-protocol Mode)
(CP1E N/NA-type CPU
Unit only)
A394
00 to
Serial Option Port
07
Polled Unit Communi-
cations Flags (CP1E
N30/40/60 or NA20
CPU Unit only)
00 to
Serial Option Port
15
Reception Counter
(No-protocol Mode)
(CP1E N30/40/60 or
NA20 CPU Unit only)
A400
Error code
A401
00
Other Fatal Error Flag
06
FALS Error Flag
(fatal error)
08
Cycle Time Too Long
Flag
(fatal error)
A-66
Function
The corresponding bit will be ON when
the built-in RS-232C port is communi-
cating with NT Link mode or Serial PLC
Link mode.
Bits 0 to 7 correspond to Units 0 to 7.
Indicates (in binary) the number of
bytes of data received when the built-in
RS-232C port is in no-protocol mode.
The corresponding bit will be ON when
the Serial Option port is communicat-
ing with NT link mode.
Bits 0 to 7 correspond to Units 0 to 7.
Indicates (in binary) the number of
bytes of data received when the Serial
Option port is in no-protocol mode.
When a non-fatal error (user-defined
FALS or system error) or a fatal error
(user-defined FALS or system error)
occurs, the 4-digit hexadecimal error
code is written to this word.
Note When two or more errors occur
simultaneously, the highest error
code will be recorded.
ON when a fatal error that is not
defined for A401.01 to A401.15 occurs.
Detailed information is output to the
bits of A314.
Note There are no errors that affect
this flag at this time. This flag is
reserved by the system.
ON when a fatal error is generated by
the FALS instruction. The CPU Unit will
stop operating and the ERR/ALM indi-
cator will light.
The corresponding error code will be
written to A400. Error codes C101 to
C2FF correspond to FALS numbers
001 to 511.
Note This flag will be turned OFF when
the FALS errors are cleared.
ON if the cycle time exceeds the maxi-
mum cycle time set in the PLC Setup
(the cycle time monitoring time). CPU
Unit operation will stop and the
ERR/ALM indicator on the front of the
CPU Unit will light.
Note This flag will be turned OFF when
the error is cleared.
Status
after
Settings
mode
change
ON: Communicating
Retained
Cleared
OFF: Not communi-
cating
Retained
Cleared
ON: Communicating
Retained
Cleared
OFF: Not communi-
cating
Retained
Cleared
Cleared
Cleared
OFF: No other fatal
Cleared
Cleared
error
ON: Other fatal error
ON: FALS executed
Cleared
Cleared
OFF: FALS not exe-
cuted
OFF: Cycle time
Cleared
Cleared
under max.
ON: Cycle time over
max.
CP1E CPU Unit Software User's Manual(W480)
Related
Status at
Write
flags,
startup
timing
settings
Refreshed
when there is a
normal
response to
the token.
Refreshed
when data is
received.
Refreshed
when there is a
normal
response to
the token.
Refreshed
when data is
received.
Refreshed
when error
occurs.
Refreshed
A314
when error
occurs.
Refreshed
A400
when error
occurs.
Refreshed
PLC
when the cycle
Setup
time exceeds
(Cycle
maximum.
time mon-
itoring
time)