17 Ethernet Option Board
17-6 Connection Method with the
CX-Programmer
The CX-Programmer version 9.12 or higher can be connected online to the Ethernet Option Board with
Ethernet. The connection method shows below.
In the following example, the Ethernet Option Board is connected without making any setting.
Example
A (except 1)
Display in Workstation Node Number on the Network
Type Tab in CX-Programmer's Change PLC Dialog
Box
Auto-generation in the CX-Programmer
Select Auto-detect in Workstation Node
Number
Set to 192.168. 250. A (A is any value except 1)
Set IP address in Windows' Local Area Connection –
Properties – Internet Protocol (TCP/IP) - Properties
Computer CX-Programmer
Network type Ethernet
IP address
Decision direction
FINS node address
Precautions for Correct Use
Precautions for Correct Use
Confirm the Communications Settings on the Serial Option Port Tab in the PLC Settings Dialog
Box of the CP1E CPU Unit. If the mode is set to Host Link and the baud rate to 9,600 or other
values except 115,200, the CP1E CPU Unit cannot be connected with Ethernet. ERR LED of the
Ethernet Option Board will be lit. Change the PLC Settings by USB port.
17-36
FINS node address
Ethernet
Computer
192.168. 250.A
(Set by manual on Windows)
A
(Auto-generation in the
CX-Programmer)
Default: 1
IP address
Default: 192.168. 250. 1
Ethernet Option Board
Ethernet Option Board
192.168. 250.1
(Default)
1
(Default)
CP1E CPU Unit Software User's Manual(W480)