Address
Name
Words
Bits
A540
00
Pulse Output 0
Reset Bit
08
Pulse Output 0
CW Limit Input Signal
Flag
09
Pulse Output 0
CCW Limit Input Sig-
nal Flag
10
Pulse Output 0
Positioning Com-
pleted Signal
A541
00
Pulse Output 1
Reset Bit
08
Pulse Output 1
CW Limit Input Signal
Flag
09
Pulse Output 1
CCW Limit Input Sig-
nal Flag
10
Pulse Output 1
Positioning Com-
pleted Signal
A-74
Function
The pulse output 0 PV (contained in
A276 and A277) will be cleared when
this bit is turned ON.
This is the CW limit input signal for
pulse output 0, which is used in the
origin search. To use this signal, write
the input from the actual sensor as an
input condition in the ladder program
and output the result to this flag.
This is the CCW limit input signal for
pulse output 0, which is used in the
origin search. To use this signal, write
the input from the actual sensor as an
input condition in the ladder program
and output the result to this flag.
This is the positioning completed input
signal used in the origin search for
pulse output 0. The input signal from
the servo driver is output to this bit
from the ladder program to enable
using the signal.
The pulse output 1 PV (contained in
A278 and A279) will be cleared when
this bit is turned ON.
This is the CW limit input signal for
pulse output 1, which is used in the
origin search. To use this signal, write
the input from the actual sensor as an
input condition in the ladder program
and output the result to this flag.
This is the CCW limit input signal for
pulse output 1, which is used in the
origin search. To use this signal, write
the input from the actual sensor as an
input condition in the ladder program
and output the result to this flag.
This is the positioning completed input
signal used in the origin search for
pulse output 1. The input signal from
the servo driver is output to this bit
from the ladder program to enable
using the signal.
Status
after
Status at
Settings
mode
startup
change
Retained
Cleared
Retained
Cleared
Retained
Cleared
Retained
Cleared
Retained
Cleared
Retained
Cleared
Retained
Cleared
Retained
Cleared