Omron CP1E CPU UNIT SOFTWARE User Manual page 350

Cp1e cpu unit software
Table of Contents

Advertisement

18 Programming Device Operations
Window Frames
You can drag the frames in the window to display different views of the program in the Ladder Sec-
tion Window. The window can be split into up to four sections.
Monitoring Specified Addresses
You can specify addresses to check bit status and word contents.
1
While online, select Window - Watch Window from the View Menu.
2
Input an address.
The bit status or word contents will
be displayed. For BOOL data, 0 indi-
cates OFF.
Additional Information
• When entering an address, place a period between the word address and bit number. For
example, to input the address of bit 04 in CIO 0, input "0.04."
• An address can be input by dragging it from the Ladder Section Window and dropping it into
the Watch Window. By dragging and dropping the header of a rung, all of the addresses on
that rung can be input.
18-24
CP1E CPU Unit Software User's Manual(W480)

Advertisement