Preparing for Operation and Monitoring
D Parameter Settings in n001
Key sequence
Indicator
In approximately
1 s.
H Reading the Parameter Set Value (rEd)
• To read the parameter set values in the Inverter with the EEPROM of the Digital Operator, set n176 for
parameter copy function selection to rEd.
D Procedure to Read the Parameter Set Values
Key sequence
Indicator
Completes
or
Note Be sure to set n177 for parameter read-prohibit selection to 1 so that the parameters can be read.
3-14
Display
example
Power ON
Press the Mode Key repeatedly until the PRGM
indicator is lit.
Check that "n001" is displayed.
Press the Enter Key.
The data of the specified parameter number is
displayed.
Press the Increment Key repeatedly to display the
figure "4." At that time the display flashes.
Press the Enter Key so that the set value will be
entered and the data display will be lit.
The parameter number will be displayed again in
approximately 1 s.
Display
example
Check that the PRGM indicator is lit. If the PRGM is
not lit, press the Mode Key repeatedly until the PRGM
indicator is lit.
Use the Increment or Decrement Key to display n176.
Press the Enter Key. Then "rdy" will be displayed.
Use the Increment Key to display "rEd."
Press the Enter Key so that the parameter set values
in the Inverter will be read by the EEPROM of the
Digital Operator, during which the display flashes.
When the set values have been all read, "End" will be
displayed.
Press the Mode or Enter Key. The parameter number
(n176) will be displayed again.
Chapter 3
Explanation
Explanation