Omron SYSDRIVE 3G3MV SERIES User Manual page 48

Sysdrive 3g3mv series multi-function compact inverter
Hide thumbs Also See for SYSDRIVE 3G3MV SERIES:
Table of Contents

Advertisement

Design
Symbol
Out-
MA
Multi-function contact out-
p
put
put (Normally open: Fault)
MB
Multi-function contact out-
put (Normally closed:
Fault)
MC
Multi-function contact out-
put common
P1
Multi-function photocoupler
output 1 ( During opera-
tion )
P2
Multi-function photocoupler
output 2 ( Frequency
matching )
PC
Multi-function photocoupler
output common
AM
Multi-function analog out-
put
AC
Multi-function analog out-
put common
Com-
R+
Receiver side
mu-
R–
nica
nica-
S+
Sender side
tions
tions
S–
Note 1. Parameter settings can be used to select various functions for multi-function inputs 1 to 7,
multi-function contact outputs, and multi-function photocoupler outputs. The functions in
parentheses are the default settings.
Note 2. NPN is the default setting for these terminals. Wire them by providing a common ground. No
external power supply is required.
Note 3. To provide an external power supply and wire the terminals through a common positive line,
set SW1 to PNP and use a 24 V DC ±10% power supply.
2-16
Name
Relay output
1 A max. at 30 V DC
1 A max. at 250 V AC
Open collector output 50 mA max.
at 48 V DC
• Analog output: 2 mA max. at 0 to 10 V DC
• Pulse train output (max. output voltage: 12 V DC)
(See note 4.)
When Used as Voltage Output
Output voltage (insulation type)
+5 V
+10 V
When External Power Supply is Used
External power supply (V)
12 V DC (±5%)
Note Do not use a 5-V DC or 24-V DC external power sup-
Conforming to RS-422/485
Specification
30
C
Load impedance
1.5 kΩ min.
10 kΩ min.
Input current (mA)
from external power
supply
16 mA max.
ply. Doing so can cause internal circuit damage or
malfunctioning.
g
Chapter 2
Load
imped-
ance
External
power
supply
Load
12 V DC
imped-
ance
Input
current
16 mA
max.
External power
supply ground

Hide quick links: