Advanced Operation
Motor code
Power supply voltage
0
200 V AC
1
2
3
4
5
6
7
8
9
10
40 V AC
20
21
22
23
24
25
26
27
28
29
30
n140
Energy-saving Control Coefficient
K2
Setting
0.0 to 6,550
range
Note 1. The default setting varies with the capacity of the Inverter model.
Note 2. The constant automatically changes according to the motor code in n158. For the fine-tuning
of this parameter, set the motor code in advance.
Set Values
• When the output frequency is constant for a certain period while the Inverter is in effective energy-sav-
ing control, the Inverter is set to the primary level of energy-saving control by this parameter.
• Motor constants vary with the motor manufacturer. Therefore, the fine-tuning of the parameter is
required to find the ideal value. Fine-tune the parameter while the Inverter is operating at constant
frequency so that the output power will be minimum.
n143
Power Averaging Time
Setting
1 to 200
range
Motor capacity
0.1 kW
0.2 kW
0.4 kW
0.75 kW
1.5 kW
2.2 kW
3.0 kW
3.7 kW
4.0 kW
5.5 kW
7.5 kW
0.1 kW
0.2 kW
0.4 kW
0.75 kW
1.5 kW
2.2 kW
3.0 kW
3.7 kW
4.0 kW
5.5 kW
7.5 kW
Register
018C Hex
Unit of
0.1
setting
Register
018F Hex
Unit of
1 (24 ms)
setting
Chapter 6
Energy-saving control
coefficient K2 (n140)
481.7
356.9
288.2
223.7
169.4
156.8
156.8
122.9
122.9
94.8
72.7
963.5
713.8
576.4
447.4
338.8
313.6
245.8
245.8
245.8
189.5
145.4
Changes during
No
operation
Default setting
See note
1
Changes during
No
operation
Default setting
1
6-7