Basic Operation
• If acceleration/deceleration time selection 2 (setting: 27) is not set at any multi-function input from
n050 to n056, the Inverter will determine that the acceleration/deceleration selection 2 is set to OFF,
and select the acceleration/deceleration time.
In the same way, if acceleration/deceleration time selection 1 (setting: 11) is not set at any multi-func-
tion input, the Inverter will determine that the acceleration/deceleration selection 1 is set to OFF, and
select the acceleration/deceleration time.
• Deceleration time 2 is used if emergency stop (setting: 19 to 22) is set at any multi-function input from
n050 to n056 and if decelerate to a stop (setting: 0) is set at stopping mode selection n005.
n019
Acceleration Time 1
Setting
0.0 to 6,000 (s) (See note 1.)
range
n020
Deceleration Time 1
Setting
0.0 to 6,000 (s) (See note 1.)
range
n021
Acceleration Time 2
Setting
0.0 to 6,000 (s) (See note 1.)
range
n022
Deceleration Time 2
Setting
0.0 to 6,000 (s) (See note 1.)
range
n041
Acceleration Time 3
Setting
0.0 to 6,000 (s) (See note 1.)
range
n042
Deceleration Time 3
Setting
0.0 to 6,000 (s) (See note 1.)
range
n043
Acceleration Time 4
Setting
0.0 to 6,000 (s) (See note 1.)
range
n044
Deceleration Time 4
Setting
0.0 to 6,000 (s) (See note 1.)
range
5-26
Register
0113 Hex
Unit of
0.1 s
setting
(See note
1.)
Register
0114 Hex
Unit of
0.1 s
setting
(See note
1.)
Register
0115 Hex
Unit of
0.1 s
setting
(See note
1.)
Register
0116 Hex
Unit of
0.1 s
setting
(See note
1.)
Register
0129 Hex
Unit of
0.1 s
setting
(See note
1.)
Register
012A Hex
Unit of
0.1 s
setting
(See note
1.)
Register
012B Hex
Unit of
0.1 s
setting
(See note
1.)
Register
012C Hex
Unit of
0.1 s
setting
(See note
1.)
Chapter 5
Changes during
Yes
operation
Default setting
10.0
Changes during
Yes
operation
Default setting
10.0
Changes during
Yes
operation
Default setting
10.0
Changes during
Yes
operation
Default setting
10.0
Changes during
Yes
operation
Default setting
10.0
Changes during
Yes
operation
Default setting
10.0
Changes during
Yes
operation
Default setting
10.0
Changes during
Yes
operation
Default setting
10.0