Start-up
6.8 System settings
Blind mode
"Blind mode" is used to enter known or already determined timings The values to be set
have to be known.
Live mode [} 55]
should be used to set unknown timing data step-by-step.
Note
Always save data with "Force"
The timing data are only entered into memory by the "Force" command, and the image is
then displayed with the new parameters.
Entering known timing data and fine adjustment
1. Open a test pattern with a clearly defined border (e.g. SMPTE image).
2. Open the "Blind mode" menu: Main menu → Servicelevel 2 → Force Mode → Blind mode.
3. Enter the timing data into the individual input fields using the Menu, Up and Down keys.
4. Select either "For static pictures" or "For motion pictures" in line 6 in the "Blind mode"
menu and confirm using key 2.
5. Execute the "Force"
Note: For progressive timings with an image refresh rate greater than 60 Hz, only the
54
command using key 2.
SCD 19102