Main menu
Service level 2
SCD 19102
Instructions for Use, 06/2022
Function
Adjustment /
setting range
ADC calibration
Execute
DVI enhancer
Information
Status
Settings in this menu must only be carried out by service personnel.
See
Service level 2 functions [} 38]
6.4 Menu functions
Description
Automatically calibrate A/D con-
verter for the applied video level
The video level range of the sys-
tem is checked, and the monitor
set accordingly. This results in opti-
mum adjustment of the individual
RGB A/D converters to the video
source.
The calibration results in a larger
and more flexible video level range
(e.g., the full brightness is also
achieved at 700 mV if the video
level is limited at the value of 700
mV).
Note: A specific test pattern and
timing are prerequisites.
The A/D converters have already
been factory-set and need not be
readjusted.
Enhances the DVI-D signal quality
over long distances, even when
standard cable is used
Current monitor settings in the
respective picture mode can be
selected here.
•
Operating hours of the monitor
•
Temperature in the housing
(actual and maximum tempera-
ture over the complete service
life of the monitor)
•
Firmware type and version
•
OSD version
•
Configuration version
•
Current timing
•
Current source
•
Screen resolution
•
Frequency of the input signal
(line frequency and refresh
rate)
Start-up