Eizo SCD 19102 Instructions For Use Manual page 46

1.3mp 19" lcd monitor
Hide thumbs Also See for SCD 19102:
Table of Contents

Advertisement

Start-up
6.6 Service level 2 functions
Service level 2
46
Function
Adjustment /
setting range
Activated / deacti-
PLL frequency
gain adjustment
vated
Default: Deacti-
vated
Description
Note: Menu item "PLL frequency
gain" is displayed when "PLL fre-
quency gain adjustment" is acti-
vated.
The value for the PLL frequency
gain is set through the XICOR AD
converter.
Note: If "PLL frequency gain ad-
justment" is changed from acti-
vated to deactivated, menu item
"PLL frequency gain" is hidden
and the phase frequency is set to
the default value.
PLL frequency gain
Controls the level of frequency er-
ror returned to the digital PLL
Each key figure has double the
weight of the previous key figure.
0000: (minimum gain)
0111: [default]
1111: (maximum gain)
If the "PLL frequency gain" is set
too low or too high, distorted im-
ages will be displayed.
Setting the best PLL frequency
gain
The best PLL frequency gain can
be obtained with the "Check-11"
pixel on / pixel off image from the
Quantum Data 802R video test
generator.