Adjusting feed dog and needle bar linkage
10. Tighten the threaded pins (1).
11. Finish the service routine.

7.3 Aligning the needle bar linkage sideways

Fig. 33: Aligning the needle bar linkage sideways (1)
(1) - Screws
(2) - Set collars
(3) - Screw
Proper setting
If the stitch length is 0, the needle pierces exactly in the center of the
needle hole.
To align the needle bar linkage sideways:
1. Switch off the machine.
2. Disassemble the front cover ( p. 20).
3. Disassemble the head cover ( p. 21).
4. Disassemble the tensioning plate ( p. 26).
5. Position the plates (4) of the stitch regulator flush.
6. Loosen the threaded pins (1) on the set collars (2).
7. Loosen the screw (3).
Service Instructions D867 e-con - 00.0 - 08/2023
In the process, make sure that the feed dog height has the correct
setting ( p. 51).
(4) - Plates
(5) - Needle hole
(6) - Needle bar linkage