Dismantling Of The Hook Box; Needle And Thread Mechanism; Height Setting Of The Needle Bar - Dürkopp Adler 1130i-5 Instructions For Service Manual

Table of Contents

Advertisement

8
4
7
5
6
5
6
3
9
10
11
2
3
1
1
2
3
1
1
www.promelectroavtomat.ru

3.1.10 Dismantling of the hook box

When dismantling the box (1), the supplies of lubricating oil
are to be disconnected first, the fastening screws unscrewed
and, thereafter, the box is removed.
Caution ! Danger of injury!
Switch off the main switch! Before starting the
setting operation, wait until the motor stops!
- Unscrew the screw (8) from the oil tank (4) and pull the box
out from the bedplate (7).
- Disconnect the lubricating tubes with the wicks (2) and (3)
from the oil tank (4).
- Loosen only one screw (5).
- Unscrew the screws (6).
- Shift the hook box in the sense of the arrow and remove it
out from the machine.
- When mounting it, proceed inversely.
3.2

Needle and thread mechanism

7
3.2.1 Description
The take-up lever (1) is mounted in ball bearings, both at the
2
spot of its suspending on the connecting rod (2) and in the
13
mounting on the loop (12). The take-up lever is of aluminum
and is provided with a stuck-in eye for two threads. The
8
connecting rod (2) is mounted on the eccentric pin (3), by
1
means of which the thread mechanism is adjusted according
to the category of stitching. The needle rod holder (4) is
mounted through the pivot (5) in a rotating way in the arm (6).
12
In its top part, the holder is guided by the guide pin (7). The
movement for the needle feed is given to it by the connecting
rod (8) driven by the feeding shaft (9). The connecting rod (8)
is mounted by pin (13) with needle bar holder (4).
The connecting rod (10) of the needle bar (11) on the loop
4
(12) is mounted in a ball bearing and it is slidingly mounted
6
on the needle bar carrier. The mechanism is lubricated by means
of a central-wick lubricating system.
5
3.2.2 To check the handwheel angular adjustment
The handwheel (5) must be situated in its precise position
relative to the needle and thread mechanism. This position is
5
given by a pin (2), which locks the connecting rod of the
needle rod (1) through a hole in the arm (3). In this position,
4
the indicator (6) of the handwheel must show „O“. The position
0
is fixed by the handwheel screw (4) contacting a small flat
o
surface provided on the upper shaft.
The correct adjustment of the angular position has been car-
ried out at the producer‘s.
6
Caution ! Danger of injury!
Switch off the main switch! Before starting the
setting operation, wait until the motor stops!

3.2.3 Height setting of the needle bar

At the moment, when the hook point passes around the needle,
the upper edge of the needle eye must be about 1 mm below
the hook point. In an opposite case, it is necessary to set the
height of the needle bar as follows:
Caution ! Danger of injury!
Switch off the main switch! Before starting the
setting operation, wait until the motor stops!
- Remove the front guard.
- Loosen the screws (1) of the needle bar carrier
- Set the correct height of the needle bar and tighten anew
the screws (1).
Caution !
An incorrect setting of the needle bar height may
cause the striking of the hook point against the
needle.
5

Advertisement

Table of Contents
loading

Table of Contents