Aligning the needle bar linkage

9
Order
First check the following setting:
• A straight and undamaged needle has to be inserted
Proper setting
Position the upper and lower stitch length adjusting wheel to 0.
 The needle pierces exactly in the center of the feed-dog needle hole.
9.1 Moving the needle bar linkage sideways
Cover
• Arm cover (
• Head cover ( p. 16)
Fig. 31: Aligning the needle bar linkage sideways
Setting steps
1. Set the upper and lower stitch length adjusting wheel to 0.
2. Loosen the setscrews (1) on the two adjusting rings (2) at the right-
Service Instructions 867 - 03.0 - 10/2017
Aligning the needle bar linkage
( Operating manual Section, Inserting and replacing the needle)
WARNING
Risk of injury
Crushing injuries from moving parts.
Switch off the sewing machine before aligning the
needle bar linkage sideways.
p. 15)
(1) - Setscrews
(2) - Adjusting screws
hand end of the shaft for the needle bar linkage.
(3) - Needle hole
(4) - Needle bar linkage