Adjusting The Needle Guard - Dürkopp Adler D867 e-con Service Instructions Manual

Table of Contents

Advertisement

2. Disassemble the head cover ( p. 21).
3. Loosen the screw (2).
4. Move the height of the needle bar (1) such that the hook tip is in
5. Tighten the screw (2).
6. Finish the service routine.

8.4 Adjusting the needle guard

The needle guard prevents contact between needle and hook tip.
Order
First, check the following settings:
Fig. 42: Adjusting the needle guard
(1) - Needle
(2) - Screw
Proper setting
The needle guard (3) pushes the needle away just enough so that it
cannot be touched by the hook tip.
To adjust the needle guard:
1. Execute the service routine Needle-Hook > Timing ( p. 14).
 The software is used to define the necessary presettings on the
58
the middle of the lower third of the groove for the needle.
When doing so, make sure that you do not twist the needle to the side.
The groove of the needle must face the hook.
• Looping stroke position ( p. 54)
• Hook side clearance ( p. 53)
• Needle bar height ( p. 57)
machine.
Position of the hook and needle
(3) - Needle guard
Service Instructions D867 e-con - 00.0 - 08/2023

Advertisement

Table of Contents
loading

Table of Contents