Programming

19.4.8 Setting the Stitch length parameters

Various settings can be made for the stitch length. The possibilities are
explained in more detail in the table.
Icon
Service Instructions D867 e-con - 00.0 - 08/2023
NOTICE
Property damage may occur!
The machine and the sewing equipment may be damaged.
ALWAYS enter the maximum possible stitch length after changing
the sewing equipment.
Menu items
Max. stitch length
Maximum stitch length possible during
sewing; this will vary depending on the
sewing equipment and MUST be adjusted
when changing the sewing equipment.
Manual stitch length adjustment
Stitch regulator for manual adjustment of
the stitch length active or inactive; optional
equipment.
Value range
• Value range
03.0 - 12.0 [mm],
depending on
subclass
• Value range
On/Off