Replace the Heart Rate Hand Sensors

Tools Required: Phillips Screwdriver
Estimated Repair Time: 30 Minutes
1. Remove and save the two Phillips screws that
secure the right or left heart rate hand sensors to
the Ergo Bar assembly or the User Arms.
2. Note the location of the wires connected to the
heart rate hand sensors. This will simplify reas-
sembly.
3. Disconnect the heart rate wires from the hand
sensors
4. Install the new heart rate hand sensors in reverse
order using the screw removed and saved in the
fi rst step.

Replace the Resistance / Stride Length Buttons

Tools Required: Phillips Screwdriver
Estimated Repair Time: 15 minutes
1. Remove the 2 screws on the backside of the resistance /
stride length buttons.
2. Pull the front half away from the back piece of the button
assembly.
3. Disconnect the wires from the button assembly.
4. Install new button assembly in reverse order.
Heart Rate Hand Sensor
Phillips Screws
Heart Rate
Hand Sensor
Phillips Screws
27
Front View
Resistance
Buttons
Rear View