Replace the AC Inlet or ON/OFF Switch

Tools Required: Phillips Screwdriver, Needle
Nose Pliers
Estimated Repair Time: 30 Minutes
1. Turn the cross-trainer power switch OFF.
2. Unplug the line cord from the wall outlet.
3. Remove and save the four Phillips screws
that secure the power bracket cover to
the power bracket. Save the power
bracket cover.
4. Remove and save the two screws that
secure the AC inlet to the power bracket.
5. Disconnect the black, white, and green
wires from the AC inlet. Note the position
of the wires on the AC inlet. This will
simplify reassembly.
6. Remove the two back shrouds.
7. Remove the four Phillips screws that
secure the ON/OFF switch mounting
plate.
8. Note where the wires are connected to
the back of the ON/OFF switch. This will
simplify reassembly.
9. Disconnect the wires.
10. The ON/OFF switches snap into the
mounting plates from the front. Remove
the old switch by pushing on the back of
the switch.
11. Install the new AC inlet in reverse order
using the screws removed and saved in the previous steps.