Rxyq192/216/240Aa - Daikin VRV EMERION RXYQ-AATJA Service Manual

Hide thumbs Also See for VRV EMERION RXYQ-AATJA:
Table of Contents

Advertisement

Functional Parts Layout
2.4

RXYQ192/216/240AA

Front View
Fan motor 2
(M2F)
Thermistor
(Electrical box air outlet)
(R4T)
Solenoid valve
(Hot gas bypass)
(Y3S)
Thermistor
(Heat exchanger liquid pipe)
(R2T)
Thermistor
(Heat exchanger left deicer)
(R10T)
Thermistor
(Heat exchanger deicer)
(R3T)
Bird's Eye View
Thermistor
(Heat exchanger right gas pipe)
(R11T)
Thermistor
(Heat exchanger left gas pipe)
(R12T)
Thermistor (Outdoor air)
(R1T)
Electronic expansion valve
(Heat exchanger left)
(Y6E)
Electronic expansion valve
(Heat exchanger main)
(Y1E)
Thermistor
(Heat exchanger left liquid pipe)
(R9T)
Electronic expansion valve
(Refrigerant auto charge)
(Y4E)
Thermistor
(M2C discharge pipe)
(R15T)
Crankcase heater
(E2HC)
Compressor 2
(M2C)
53
A
Solenoid valve
(Four way valve)
High pressure sensor
(Y5S)
(S1NPH)
SiUS342303E
Fan motor 1
(M1F)
Solenoid valve
(Oil separator oil return 1)
(Y2S)
Solenoid valve
(Accumulator oil return)
(Y4S)
Low pressure sensor
(S1NPL)
Thermistor
(Suction pipe before accumulator)
(R5T)
High pressure switch (M2C)
(S2PH)
High pressure switch (M1C)
(S1PH)
Solenoid valve
(Oil separator oil return 2)
(Y1S)
Thermistor
(M2C compressor body)
(R16T)
Thermistor
(M1C compressor body)
(R14T)
Thermistor
(M1C discharge pipe)
(R13T)
Crankcase heater
(E1HC)
Compressor 1
(M1C)
C: 0P710323D
Part 2 Refrigerant Circuit