Daikin VRV EMERION RXYQ-AATJA Service Manual page 199

Hide thumbs Also See for VRV EMERION RXYQ-AATJA:
Table of Contents

Advertisement

SiUS342303E
No.
Item
1
Heat pump
Heat pump would be resumed
lockout release
when the outdoor air temperature
47
differential
is recovered by differential above
the heat pump lockout
temperature.
Outdoor > 50 m
Height difference setting max. 110
49
(164 ft) above
m (361 ft).
indoor
Auxiliary heater
Auxiliary heater is allowed to
maximum
energize when the ambient
allowable
temperature is smaller than the
temperature
auxiliary heater maximum
allowable temperature.
50
Sequence multi
Sequence addressing between
51
outdoor
master and sub units.
Auxiliary heater
Auxiliary heater is not allowed to
maximum
energize when the outdoor air
allowable
temperature is recovered by
52
temperature
differential above the auxiliary
release
heater maximum allowable
differential
temperature.
Cooling/Heating
Adjust cooling and heating capacity
capacity learning
learning control
62
control
Heat pump
Heat pump is locked out when the
lockout
outdoor air temperature is smaller
temperature
than the heat pump lockout
temperature.
65
VRTsmart
Used to change upper limit of
control
target evaporation temperature in
Te upper limit
VRTsmart control.
76
Part 5 Field Settings and Test Operation
Description
SEG
1
2.
2.
2.
2.
2.
2.
2.
2.
7 segment
display
Description
SEG
SEG
2
3
2.8°C (5°F)
5.6°C (10°F)
4
7
8.3°C (15°F)
Off (max. 50 m (164 ft))
4
9
On (max 110 m (361 ft))
–17.7°C (0°F)
–15°C (5°F)
–12.2°C (10°F)
–9.4°C (15°F)
–6.6°C (20°F)
–3.8°C (25°F)
–1.1°C (30°F)
1.6°C (35°F)
4.4°C (40°F)
5
0
7.2°C (45°F)
10°C (50°F)
12.7°C (55°F)
15.5°C (60°F)
18.3°C (65°F)
Auxiliary heater always not
allowed
Auxiliary heater always
allowed
Automatic
5
1
Forced master
Forced sub
2.8°C (5°F)
5.6°C (10°F)
8.3°C (15°F)
5
2
OFF
Cooling adjustment
6
2
Heating adjustment
Cooling and heating
adjustment
–26.1°C (–15°F)
–23.3°C (–10°F)
–20.5°C (–5°F)
–17.7°C (0°F)
–15°C (5°F)
–12.2°C (10°F)
–9.4°C (15°F)
6
5
–6.6°C (20°F)
–3.8°C (25°F)
–1.1°C (30°F)
1.6°C (35°F)
4.4°C (40°F)
7.2°C (45°F)
10°C (50°F)
Forced heat pump lockout
Low 1
Low 2
Low 3
Low 4
7
6
Low 5
Low 6
Standard
High
Field Setting from Outdoor Unit
7 segment
display
Range
SEG
SEG
1
2
1
1
1
1
1
1
1
1
1
1
1
SEG
3
0
1
2
0
1
0
1
2
3
4
5
6
7
8
9
0
1
2
3
4
5
0
1
2
0
1
2
0
1
2
3
0
1
2
3
4
5
6
7
8
9
0
1
2
3
4
0
1
2
3
4
5
6
7
192