SiUS342303E
First
Mode
Code
Setting Contents
No.
No.
(Note 2)
0
Setting of airflow rate
Airflow direction setting
1
Swing pattern settings
2
13 (23)
Setting of airflow direction
4
adjustment range
Setting of static pressure
5
selection
External static pressure
6
settings
Optional kit setting (UV lamp
4
+ humidifier + economizer)
Dry mode set temperature
5
14 (24)
Mold proof operation setting
9
11
Gas furnace test mode
0
Drain pump operation setting
Humidification when heating
1
thermostat is OFF
Setting of direct duct
2
connection
15 (25)
Interlocked operation
3
between humidifier and drain
pump
Individual setting of
5
ventilation
Display of error codes on the
1b
4
remote controller
0
Room temperature display
Thermistor sensor for auto
changeover and setback
1
control by the remote
controller
1c
Access permission level
3
setting
Remote controller thermostat
10-15
offset
2
Setback availability
1e
Setting "restricted / permitted"
14
of airflow block
Note(s)
1. Settings are made simultaneously for the entire group, however, if you select the mode No.
2. The mode numbers inside parentheses cannot be used by wireless remote controllers, so they
3. Do not make settings other than those described above. Nothing is displayed for functions the
4. 88 or Checking the connection. Please stand by. may be displayed to indicate the remote
Part 5 Field Settings and Test Operation
01
Standard
4-direction
airflow
All direction
synchronized
swing
Draft prevention
Standard
Room
temperature
—
OFF
—
Not equipped
Not equipped
Not
interlocked
Normal
—
Not displayed
Utilize the return
air thermistor
Level 2
N/A
inside parentheses, you can also set by each individual unit. Setting changes however cannot
be checked except in the individual mode for those in parentheses.
cannot be set individually. Setting changes also cannot be checked.
indoor unit is not equipped with.
controller is resetting when returning to the normal mode.
Second Code No.
02
03
High ceiling 1
High ceiling 2
2-direction
3-direction airflow
airflow
Facing
—
swing
Ceiling soiling
Standard
prevention
High static
—
pressure
Refer to page on the right for details.
Refer to page on the right for details.
Same as cooling
mode set
—
temperature
For high
Standard
humidity areas
Low heat
High heat
ON
OFF
Equipped
Equipped
Interlocked
Individual
—
Two-digit display
—
Displayed
—
Utilize the
remote
—
controller
thermistor
Level 3
—
Refer to page on the right for details.
Heat only
Cool only
Refer to page on the right for details.
Field Settings for Indoor Unit
Reference
04
—
—
—
—
—
—
—
—
—
—
—
—
—
—
—
—
Four-digit
display
—
—
—
Cool/heat
Page
171
172
172
172
173
173
174
174
175
175
175
175
175
176
176
176
176
176
177
177
178
178
156