Add/Edit Ipv4 Static Route - ZyXEL Communications XMG1915 Series User Manual

8-16-port multi-gigabit smart managed switch
Table of Contents

Advertisement

Table 172 NETWORKING > Static Routing > IPv4 Static Route (continued)
LABEL
Add/Edit
Delete

52.2.1 Add/Edit IPv4 Static Route

Click Add/Edit, or select an entry and click Add/Edit in the NETWORKING > Static Routing > IPv4 Static
Route screen to display this screen.
Figure 221 NETWORKING > Static Routing > IPv4 Static Route > Add/Edit
The following table describes the related labels you use to create a static route.
Table 173 NETWORKING > Static Routing > IPv4 Static Route > Add/Edit
LABEL
Active
Name
Destination IP
Address
IP Subnet Mask
Gateway IP
Address
Metric
Apply
Clear
Cancel
Chapter 52 Static Route
DESCRIPTION
Select an entry's check box to select a specific entry. Otherwise, select the check box in the
table heading row to select all entries.
Click Add/Edit to add a new entry or edit a selected one.
Click Delete to remove the selected entries.
DESCRIPTION
This field allows you to activate or deactivate this static route.
Enter a descriptive name (up to 10 printable ASCII characters except [ ? ], [ | ], [ ' ], [ " ] or [ , ]) for
identification purposes.
This parameter specifies the IP network address of the final destination.
Enter the subnet mask for this destination. Routing is always based on network number. If you
need to specify a route to a single host, use a subnet mask of 255.255.255.255 in the subnet mask
field to force the network number to be identical to the host ID.
Enter the IP address of the gateway. The gateway is an immediate neighbor of your Switch that
will forward the packet to the destination. The gateway must be a router on the same segment
as your Switch.
The metric represents the "cost" of transmission for routing purposes. IP routing uses hop count as
the measurement of cost, with a minimum of 1 for directly connected networks. Enter a number
that approximates the cost for this link. The number need not be precise, but it must be between
1 and 15. In practice, 2 or 3 is usually a good number.
Click Apply to save your changes to the Switch's run-time memory. The Switch loses these
changes if it is turned off or loses power, so use the Save link on the top navigation panel to save
your changes to the non-volatile memory when you are done configuring.
Click Clear to clear the fields to the factory defaults.
Click Cancel to not save the configuration you make and return to the last screen.
XMG1915 Series User's Guide
306

Advertisement

Table of Contents
loading

This manual is also suitable for:

Xmg1915-10ep

Table of Contents