SRX5400 Cooling System

The cooling system consists of the following components:
• Fan tray
• Air filter
The cooling system components work together to keep all firewall components within the acceptable
temperature range (see
device has one fan tray and one air filter that install vertically in the rear of the device.
Two types of fan trays are available:
• The standard capacity fan tray has three fans that operate at 216 cubic feet per minute (CFM) at full
speed and is adequate for firewalls in which standard-capacity power supplies are installed.
• The high-capacity fan tray has three fans that operate at 289 cubic feet per minute (CFM) at full
speed and is required when high-capacity power supplies are installed.
Figure 7 on page
21,
Figure 8 on page
22, and
Figure 9 on page 22