Installing the SRX5400 Firewall Chassis in the Rack Manually

To install the device in the rack (see
CAUTION: If you are installing more than one firewall in a rack, install the lowest one
first. Installing a firewall in an upper position in a rack or cabinet requires a lift.
CAUTION: Before front mounting the firewall in a rack, have a qualified technician
verify that the rack is strong enough to support the firewall's weight and is adequately
supported at the installation site.
CAUTION: Lifting the chassis and mounting it in a rack requires two people. The empty
chassis weighs approximately 65 lb (29 kg).
1. Ensure that the rack is in its permanent location and is secured to the building. Ensure that the
installation site allows adequate clearance for both airflow and maintenance.
2. Position the firewall in front of the rack or cabinet, centering it in front of the mounting shelf. Use a
pallet jack if one is available.
3. With one person on each side, hold onto the bottom of the chassis and carefully lift it onto the
mounting shelf.
Figure 78 on page
185):