Moving The Mounting Brackets For Center-Mounting The Srx5400 Firewall - Juniper SRX5400 Hardware Manual

Firewall
Hide thumbs Also See for SRX5400:
Table of Contents

Advertisement

Figure 73: Installing the Mounting Hardware for an Open-Frame Rack
Moving the Mounting Brackets for Center-Mounting the SRX5400
Firewall
Two removable mounting brackets are attached to the mounting holes closest to the front of the chassis.
You can move the pair of brackets to another position on the side of the chassis for center-mounting the
firewall.
To move the mounting brackets from the front of the chassis toward the center of the chassis:
1. Remove the three screws at the top and center of the bracket.
2. Pull the top of the bracket slightly away from the chassis. The bottom of the bracket contains a tab
that inserts into a slot in the chassis.
3. Pull the bracket away from the chassis so that the tab is removed from the chassis slot.
4. Insert the bracket tab into the slot in the bottom center of the chassis.
5. Align the bracket with the two mounting holes located toward the top center of the chassis.
There is no mounting hole in the center of the chassis that corresponds to the hole in the center of
the bracket.
6. Insert the two screws at the top of the bracket and tighten each partially.
Two screws are needed for mounting the bracket on the center of the chassis. You do not need the
third screw.
7. Tighten the two screws completely.