Table 3: Front Panel of the Craft Interface
Component
8/9
NOTE: The SCB must be installed in the firewall for the craft interface to obtain power.
SRX5400 Firewall Craft Interface Alarm LEDs and Alarm Cutoff/Lamp
Test Button
Two large alarm LEDs are located at the upper right of the craft interface. The circular red LED lights to
indicate a major alarm condition that can result in a system shutdown. The triangular yellow LED lights
to indicate a less severe minor alarm condition that requires monitoring or maintenance. Both LEDs can
be lit simultaneously. A condition that causes an LED to light also activates the corresponding alarm
relay contact on the craft interface.
To deactivate the major and minor alarms, press the button labeled ACO/LT (for "alarm cutoff/lamp
test"), which is located to the right of the alarm LEDs. Deactivating an alarm turns off both LEDs and
deactivates the device attached to the corresponding alarm relay contact on the craft interface.
Table 4 on page 12
describes the alarm LEDs and alarm cutoff button in more detail.
Table 4: Alarm LEDs and Alarm Cutoff/Lamp Test Button
Shape
Label
Major Alarm
(Continued)
Description
SCB and MPC LEDs, and MPC online/
offline buttons
The card LEDs are located along the
bottom edge of the craft interface and
are labeled 0 for the bottom slot
reserved for the SCB and 0/1, 1, and 2
for the remaining slots.
Color
State
Description
Red
On steadily
Critical alarm LED—Indicates a critical condition that can
cause the device to stop functioning. Possible causes
include component removal, failure, or overheating.
Reference
See
"SRX5400 Firewall Craft Interface
Card OK/Fail LEDs" on page 14
See
"SRX5400 Firewall Craft Interface
Online/Offline Buttons" on page 15
12