Toshiba B-EX Series Key Operation Specification page 95

Hide thumbs Also See for B-EX Series:
Table of Contents

Advertisement

8.4.2.17 THRESHOLD SELECT
・ REFLECT
Selects the threshold value for the reflective sensor.
・ TRANS.
Selects the threshold value for the transmissive sensor.
* For B-EX4T3-HS V2.1 or later, this setting is disregarded since this is carried out by means of the
sensor setting in ISSUE CONTROL (refer to Section 9.11).
8.4.2.17.1 REFLECT
<In the case of models other than B-EX4T3-H>
・ MANUAL SET
・ COMMAND SET
<In the case of B-EX4T3-H>
・ MANUAL1 SET
・ MANUAL2 SET
・ MANUAL3 SET
・ MANUAL4 SET
・ MANUAL5 SET
・ COMMAND SET
8.4.2.17.2 TRANS.
<In the case of models other than B-EX4T3-H>
・ MANUAL SET
・ COMMAND SET
<In the case of B-EX4T3-H>
・ MANUAL1 SET
・ MANUAL2 SET
・ MANUAL3 SET
・ MANUAL4 SET
・ MANUAL5 SET
・ COMMAND SET
8.4.2.18 ENERGY TYPE
・ TRANSFER
・ DIRECT
This parameter is intended to make the printer perform appropriate printing for the supplies (media such
as labels and tag, and ribbon) to be used. Use of a different supply from the setting may cause poor
printing.
For details of the appropriate settings, refer to the Supply Specification.
Note:
If "CN" is selected for the parameter clear destination, the ENERGY TYPE parameter is not
displayed in the software set menu.
Applicable model: B-EX4T1-G/T-QM/CN C1.5 or later
<Supplement>
If "CN" is selected for the parameter clear destination, this parameter is not displayed on the menu.
Therefore, the initial value of this parameter cannot be changed. (The initial value is fixed. See Section
8.8.3 PARAMETER CLEAR.)
The value set in the threshold mode takes effect.
The value set by command takes effect.
The value set in the threshold mode 1 takes effect.
The value set in the threshold mode 2 takes effect.
The value set in the threshold mode 3 takes effect.
The value set in the threshold mode 4 takes effect.
The value set in the threshold mode 5 takes effect.
The threshold set by command takes effect.
The value set in the threshold mode takes effect
The value set by command takes effect.
The value set in the threshold mode 1 takes effect.
The value set in the threshold mode 2 takes effect.
The value set in the threshold mode 3 takes effect.
The value set in the threshold mode 4 takes effect.
The value set in the threshold mode 5 takes effect.
Threshold set by command takes effect.
B-EX4T2-G/T-QM/CN C1.3 or later
90