7b.
Detail: NG (1)
[Threshold setting]
8a. Sensor fine
adjustment
Judgment result
Display example
The threshold setting judgment result is indicated with one of the following icon types.
No.
Display example
1
2
3
4
5
6
↓ Press the [RIGHT] key.
Displayed item
Sensor type
Result (Text)
Result (Graph)
Key operation guide
Sensor type
Result (Text)
Result (Graph)
Key operation guide
Icon name
Explanation
OK (Mid.)
The print position is detectable with the media sensor.
The threshold is at the midpoint between the peak and
the baseline.
OK (High)
The threshold is near the peak voltage, so the
detection of a gap or black marks may fail if the
difference between the threshold and the peak voltage
is very small. (Adjusting the threshold to the midpoint
between the peak and the baseline enables a more
accurate detection.)
OK (Low)
The threshold is near the baseline voltage, so the
detection of a gap or black marks may fail if the
difference between the threshold and the base voltage
is very small. (Adjusting the threshold to the midpoint
between the peak and the baseline enables a more
accurate detection.)
NG (1)
The print position is not detectable with the media
sensor. Sensor adjustment is necessary.
NG (1)
The print position is not detectable with the media
sensor. Sensor adjustment is necessary.
(Threshold ≤ Baseline)
NG (2)
The print position is not detectable with the media
sensor.
(Calibration may enable print position detection, but it
is very difficult.)
The operation is same as
that for 8.5.9 reflective
sensor fine adjustment.
Explanation
The calibration result is shown.
Pressing the [FEED] key returns the screen to the
media sensor selection and enables a threshold
setting.
Pressing the [RIGHT] key shows the measured
voltages.
Pressing
the
[ENTER]
threshold setting. (*)
The result of the fine adjusted threshold setting is
shown.
Pressing the [LEFT] key enables setting a
threshold fine adjustment value.
The function by pressing the [RIGHT] and
[ENTER] keys is the same way as above.
16
Pressing the [LEFT] key
returns the screen to "6b.
Judgment".
Pressing
the
[PAUSE],
[ENTER]
or
[CANCEL]
key returns the screen to
"6a. Judgment".
The threshold value is
stored in the location with
the
allocation
number
selected in "3.1 Allocation
number selection".
key
terminates
the