Toshiba B-EX Series Key Operation Specification page 22

Hide thumbs Also See for B-EX Series:
Table of Contents

Advertisement

Details of the result
Display example
Note:
For B-EX4T3-H, the screen for setting a threshold value allocation number appears after a media
sensor type is selected.
Storage number selection screen
Media sensor type: REF. (PRE-PRINT)
・MANUAL1 SET (Default)
・MANUAL2 SET
・MANUAL3 SET
・MANUAL4 SET
・MANUAL5 SET
Media sensor type: TRANS. (PRE-PRINT)
・MANUAL1 SET (Default)
・MANUAL2 SET
・MANUAL3 SET
・MANUAL4 SET
・MANUAL5 SET
Key operation
[CANCEL]
[ENTER]
[UP]
[DOWN]
(Supplementary Explanation)
(1) The [PAUSE] key is invalid when it is released within 3 seconds while the printer is paused.
(2) To set the threshold, 1.5 pieces or more label shall be fed. (If the label feed amount is insufficient, the
threshold may not be properly set. In this case, the threshold setting needs to be retried.)
(3) While the print head is lifted, the [PAUSE] key is invalid even if it is held down for 3 seconds or more.
(4) When the print position is not corrected even after the threshold is set, the sensor adjustment may be
insufficient. In this case, readjust the sensor in the system mode, and set the threshold.
(When the backing paper of the label is too thick, the transmissive sensor needs to be readjusted.)
In addition, make sure that "3: Transmissive sensor (when using the pre-printed media)" or "4:
Reflective sensor (when using a manual threshold value)" is selected for sensor type of the feed
command and the issue command.
(5) Paper end and ribbon end are not detected during the threshold setting. (The setting continues as long
as the [PAUSE] key is held down even if the printer runs short of media or ribbon.)
(6) The detailed result of the calibration is shown when the [RIGHT] key is pressed while the judgment
result is displayed. The measured sensor level and the currently programmed threshold fine
adjustment value can be checked.
Fine adjustment value = Peak voltage – Threshold voltage
(7) Pressing the [LEFT] key returns the detailed result to the judgment result display. Pressing the
[RIGHT] key causes the screen to go to the threshold fine adjustment screen. This is the same menu
with the threshold fine adjustment menu in section 8.5.9 (Reflective sensor) or 8.5.10 (Transmissive
sensor).
(8) After the threshold fine adjustment value is set, the screen returns to the result display.
Displayed item
Sensor type
Peak value
Threshold voltage
Baseline voltage
Key operation guide
Cancels the selection and returns to the previous page.
Fixes the selection and places the printer in the pause state.
Moves the cursor upward.
Moves the cursor downward.
Explanation
The calibration result and the threshold voltage
are displayed.
Pressing the [RIGHT] key enables setting a
threshold fine adjustment value.
Pressing the [LEFT] key returns the screen to the
calibration result.