Toshiba B-EX Series Key Operation Specification page 60

Hide thumbs Also See for B-EX Series:
Table of Contents

Advertisement

B-EX4T1-G, B-EX4T2-G,B-EX4D2-G:
When the power is turned off, the print distance of 8.2 m or less is rounded down when backed up.
B-EX4T1-T, B-EX4T2-T:
When the power is turned off, the print distance of 5.6 m or less is rounded down when backed up.
B-EX4T2-H, B-EX4T3-H:
When the power is turned off, the print distance of 2.8 m or less is rounded down when backed up.
PRINT1 to PRINT4
History of the last 4 print distances
CUT
Every cut operation is counted.
The count is saved every 4 cut operations.
HEAD U/D
The number of times the print head moves up and down with the solenoid for ribbon saving is counted. (A set
of up and down is counted as one.)
The count is saved every 4 head up/down operations.
RIBBON
Counted when the ribbon motor is driven while media feeding or printing. (The reverse feed is also counted.)
When the power is turned off, drive time of 10 seconds or less is rounded down when backed up.
* The counter value for the B-EX4D2 is indefinite.
SOLENOID
Counted when the ribbon saving operation is performed.
When the power is turned off, the driving time of 10 seconds or less is rounded down when backed up.
232C ERR
Counted when a parity error, overrun error or framing error occurs.
SYSTEM ERR
Counted when a system error occurs.
POWER FAIL
Counted when a momentary power interruption occurs.
<< ADJUST >>
Item
[PC] FEED
CUT
BACK
TONE (T)
TONE (D)
RBN (FW) *1
RBN (BK) *1
(RBN WIDTH
RBN(FW)
TYPE1) *1
RBN(BK)
(RBN WIDTH
RBN(FW)
TYPE2) *1
RBN(BK)
[KEY] FEED
CUT
History of print distances
Number of cut times
Head up/down count
Ribbon motor drive time
Head-up solenoid drive time
Number of times an RS-232C hardware
error occurred
Number of times a system error occurred
Number of times a momentary power
interruption occurred
Description
Feed amount fine adjustment
Cut position (or strip position) fine
adjustment
Backfeed fine adjustment
Print density fine adjustment
(Thermal transfer print mode)
Print density fine adjustment
(Direct thermal print mode)
Ribbon motor drive voltage fine
adjustment (Take-up)
Ribbon motor drive voltage fine
adjustment (Back tension)
Ribbon motor drive voltage fine
adjustment (Take-up)
Ribbon motor drive voltage fine
adjustment (Back tension)
Ribbon motor drive voltage fine
adjustment (Take-up)
Ribbon motor drive voltage fine
adjustment (Back tension)
Feed amount fine adjustment
Cut position (or strip position) fine
adjustment
55
0.0 to 3200.0 km
0 to 1000000
0 to 2000000
0 to 2000 hours
0 to 1000 hours
0 to 255
0 to 15
0 to 15
Remarks
-50.0 mm to +50.0 mm
-50.0 mm to +50.0 mm
-9.9 mm to +9.9 mm
-10 to +10 step
-10 to +10 step
-15 to +10 step
-15 to +10 step
-15 to +10 step
-15 to +10 step
-15 to +10 step
-15 to +10 step
-50.0 mm to +50.0 mm
-50.0 mm to +50.0 mm