 Issue command sending
1. While the judgment result is displayed, press the [FEED] key to terminate the threshold setting.
→ The printer is placed in the pause state.
2. Press the [RESTART] key to clear the pause state.
→ The printer is placed in the online state.
3. Hold down the [MODE] key.
→ The printer enters the user system mode.
4. Select the applicable media sensor type depending on the type specified by the issue command which
is sent to the printer by the key operation. (Pressing the [UP] and [Down] keys moves the cursor.
Pressing the [ENTER] key moves to the next page.)
Sensor type in the issue command
0: No sensor
1: Reflective sensor
2: Transmissive sensor (when using
normal labels)
3: Transmissive sensor (when using
preprinted labels)
4: Reflective sensor (when using a
manual threshold value)
5. Press the [MODE] key.
→ The user system mode menu is displayed.
6. Select "<1> RESET" and press the [ENTER] key.
→ After the printer is reset, it is placed in the online mode.
7. Send the issue command to make the printer print.
→ If a media jam occurs or the media does not stop at the print start position, retry the threshold
setting.
Setting
Whether the threshold setting succeeded or not cannot be
checked.
Select "REFLECT".
When the selected sensor type display is shown, select
"MANUAL SET" and press the [ENTER] key.
* Select the media sensor type to the one for which the
threshold was set.
Select "TRANS".
When the selected sensor type display is shown, select
"MANUAL SET" and press the [ENTER] key.
* Select the media sensor type to the one for which the
threshold was set.
No setting is necessary.
No setting is necessary.