Additional Input Tray Diagnostics; Output Device Diagnostics - Lexmark XM3250 Service Manual

Hide thumbs Also See for XM3250:
Table of Contents

Advertisement

Controller Calibration
This test must be done when the scanner controller or flatbed scanner is changed.
1
Enter the Diagnostics menu, and then navigate to:
Scanner Diagnostics > Controller Calibration
2
Touch Start.

Additional input tray diagnostics

Sensor tests
1
Enter the Diagnostics menu, and then touch Additional input tray diagnostics.
2
From the Sensor tests section, touch Start.
A dialog listing the sensor tests appears.
3
Find, and then manually toggle the sensor.
Notes:
The sensor status on the screen toggles between 1 and 0 when the sensor is properly working.
If a sensor test fails, the test failure may not indicate a failed sensor. Further troubleshooting may be
required. Check the boards and cables for possible issues.
Motor tests
1
Enter the Diagnostics menu, and then navigate to:
Additional input tray diagnostics > Motor tests
2
Select a motor, and then touch Start.
Notes:
If the motor is activated, then it is properly working.
Some motors require automatic deactivation in order to avoid secondary issues such as possible
damage and contamination.
Some tests require a special action to activate a motor such as removing a major component.
If the motor fails, the test failure may not indicate a failed motor. Further troubleshooting may be
required. Check the boards and cables for possible issues.

Output device diagnostics

Staple test
Note: This menu appears only when a finisher is installed.
1
Enter the Diagnostics menu, and then navigate to:
Output device diagnostics > Staple test
2
Select a staple job, and then check the output for any issues.