REP 12.9 Finisher Exit Gate Cam Shaft
Parts List on
PL 12.40 Item 25
Removal
Switch off the electricity to the machine. Disconnect the power cord from the customer
supply while performing tasks that do not need electricity. Electricity can cause death or
injury. Moving parts can cause injury.
1.
Separate the Finisher from the printer,
2.
Remove the left cover,
REP
12.1.
3.
Remove the exit gate actuator,
REP
4.
Remove but do not disconnect the Exit Gate Sensor,
5.
Compress the spring and remove the E-clip that secures the outer bearing in the bracket,
Figure
1.
Figure 1 Release the bearing from the bracket
6.
Move the shaft outwards to release the shaft from the Finisher, then tilt the shaft up to
remove,
Figure
2.
4 Repairs and Adjustments
REP 12.9
WARNING
GP
14.
12.7.
REP
12.6.
Figure 2 Remove the shaft from the bracket
04/2016