Component Life
The design life of the major components are shown in
actual use will vary these factors. The component life shown in
Table 1 Component Life Expectancies
Item Description
1.
Pick and nudger Rollers
2.
Separator Roller
3.
Transfer Roller
4.
Fuser
5.
Feed Roller
HFSI
The High Frequency Service Items are shown in
Table 2 High frequency service items
Item
Description
Drum Cartridge
The total sides of copies and prints
after the last HFSI reset.
Tray 1 Pick Roller Sheets fed from Tray 1 after last
HFSI reset.
Tray 2 Pick Rollers Sheets fed from Tray 2 after last
HFSI reset.
Transfer Roller
Total prints after the last HFSI
reset.
Fuser
Total prints after the last HFSI
reset.
To Reset HFSIs
1. Log into Diagnostics
2. Scroll to Printer Information
3. Scroll to HFSI
4. Select the appropriate HFSI and reset its counter.
Revised
Phaser 4600/4620/4622 Printer Service Manual
Table
1. Environmental conditions and
Table 1
is for reference only.
Print Life
200,000 pages
100,000 pages
100,000 images
200,000 images
100,000 pages
Table
2.
Recommended
life
Reference
80k impressions
PL 9.10 Item 1
150k feeds
PL 8.10 Item 3
200k feeds
PL 8.15 Item 10
100k impressions
PL 9.10 Item 2
200k impressions
PL 10.10 Item 1

SCP 6 Final Actions

Final Actions are used to evaluate the total operation of the system and to identify the actions
required to complete the service call.
Procedure
Complete the following, if a fault is identified, return to
Perform the end of call subsystem maintenance actions,
Exercise the machine in all modes, printing from all trays. If a fault message is displayed
or some other problem is evident, go to
Make a print of a customer document.
If any of the customers selections were changed, return them to the customers preferred
settings. Refer to
GP 4
System Administration Tools.
At the first service and at any subsequent service where changes are made or options are
added, print the configuration report and store it with machine log book. Discard any pre-
vious versions of the configuration report.
Remove and destroy any copies of test patterns.
Ensure the machine and service area are clean before leaving the customer premises.
Provide customer training if required.
04/2016
1-7
SCP 4
Fault Analysis:
SCP 5
Subsystem Maintenance.
SCP 4
Fault Analysis.
1 Service Call Procedures
SCP 5, SCP 6

Advertisement

Table of Contents
loading

This manual is also suitable for:

Phaser 4620Phaser 4622

Table of Contents